Page-cited permit extraction

DP Facilities Inc South LLC

Wise Co., Virginia

QA status Machine-extractedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 11790-1, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

1 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
engine generator setCummins · QSK78-G126 units2500 or 600 kW eachdiesel fuel oilSee operating-scope tablep. 4Machine-extracted from explicit permit prose: Equipment Description Rated Capacity Permit Date: Equipment to be constructed: 2500 kW EG01 - (6) Cummins QSK78-G12 diesel-fueled 4060 hp (nameplate) 8/23/2016 EG06 engine-generator sets each Cummins QSK19-G8 diesel-fueled engine- 600 kW EG07 8/23/2016 generator set 967 hp (nameplate) Specifications included in the above table are for informational purposes on

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
EO01- EO07500 hours/yeard,fire, natural disaster,or severe weather conditions. b. For periodic maintenance, testing, and operational training. (0VAO5-80-1180) 6. Operating ^ours-Each emergency diesel-fueled engine-generator set (Reference Nos. EO01- EO07) shall not operate more than 500 hours peryear,calculated monthly as the sum of each consecutive 12 month period. Compliance forthe consecutive 12 month period shall be demonstrated monthly b^ adding the total forthe most recently completed calendar month to the indMachine-extracted normative operating-hours statement; second review pending.p. 5

Permitted emission limits

0 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 0 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource

DOCUMENT HISTORY

What this document says it changes

permit to construct and operate

No superseded-document date is asserted beyond the cited source wording.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Prose fallback; verify equipment grouping.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
← Return to evidence index