Page-cited permit extraction
Amazon Data Services, Inc. IAD-61 IAD-63 IAD-65 IAD-86 IAD-155 IAD-600 IAD-018 Loudoun Co., Virginia
QA status Machine-extractedRelease dated July 29, 2026
EVIDENCE NOTE
What the public record says A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 74080-8, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.
What this record does not establish The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.
How to read the status Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.
DOCUMENT FIELDS
Permittee named in document Amazon Data Services, Inc.
Permit number 74080-8
Permit action amended or superseding permit document
Document date January 21, 2025
Facility address IAD-61 at 43736 Clubber Lane, IAD-63 at 43701 Clubber Lane, IAD-65 at 25316 Prediction Lane, IAD-86 at 25311 Prediction Lane, IAD-155 at 43774 Clubber Lane, IAD-600 at 43764 Clubber Lane, IAD-018 at 43571 John Mosby Hwy, Chantilly, Virginia 20152 (Loudoun County)
Application complete 2025-01-17
Explicitly supersedes 2022-11-21
Locality Loudoun Co.
Regional office Northern
Regulator Virginia Department of Environmental Quality MACHINE-EXTRACTED CANDIDATE
Equipment and limits, kept separate from actual use. These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.
Permitted equipment 4 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.
Reference Equipment / model Count / rating Fuel / controls Stated operating field Source 1 through 72emergency engine generator set Caterpillar · 3516C-HD 72 units 2500 kW each diesel fuel oil — See operating-scope table — p. 5 ↗ Machine-extracted from an official document equipment table; column grouping requires second review. 73emergency engine generator set Caterpillar · 3512C 1 units 1600 kW each diesel fuel oil — See operating-scope table — p. 5 ↗ Machine-extracted from an official document equipment table; column grouping requires second review. 74 through 89emergency engine generator set Caterpillar · 3516C-HD 16 units 2500 kW each diesel fuel oil — See operating-scope table — p. 5 ↗ Machine-extracted from an official document equipment table; column grouping requires second review. T1 through T8emergency engine generator set Caterpillar · 3516C 8 units 2000 kW each diesel fuel oil — See operating-scope table — p. 5 ↗ Machine-extracted from an official document equipment table; column grouping requires second review.
Operating scope Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.
Reference Limit Basis Source
Permitted emission limits 25 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.
Inspect 25 transcribed limit rows Reference Pollutant Limit Basis / scope Source Ref. Nos. 1 through 72 & 74 through 89PM10 — 0.40 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 73PM10 — 0.44 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 90PM10 — 0.17 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. T1 through T8PM10 — 0.57 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. 1 through 72 & 74 through 89PM2.5 — 0.40 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 73PM2.5 — 0.44 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 90PM2.5 — 0.17 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. T1 through T8PM2.5 — 0.57 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. 1 through 72 & 74 through 89NOx as NO2 — 48.06 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 73NOx as NO2 — 30.75 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 90NOx as NO2 — 9.31 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. T1 through T8NOx as NO2 — 38.85 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. 1 through 72 & 74 through 89NOx as NO2 — 6.09 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 73NOx as NO2 — 5.78 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 90NOx as NO2 — 2.20 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. T1 through T8NOx as NO2 — 3.96 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. 1 through 72 & 74 through 89VOC — 1.21 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 73VOC — 0.87 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. No. 90VOC — 0.10 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Ref. Nos. T1 through T8VOC — 1.13 lb/hr hourly — — p. 10 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Facility-Wide (Ref. Nos. 1 through 90 and T1 through T8)NOx as NO2 — 96.12 tpy annual — — p. 11 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Facility-Wide (Ref. Nos. 1 through 90 and T1 through T8)NOx as NO2 — 52.04 tpy annual — — p. 11 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Facility-Wide (Ref. Nos. 1 through 90 and T1 through T8)VOC — 11.03 tpy annual — — p. 11 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Facility-Wide (Ref. Nos. 1 through 90 and T1 through T8)PM10 — 3.59 tpy annual — — p. 11 ↗ Machine-extracted from an official permit limit table; header grouping requires second review. Facility-Wide (Ref. Nos. 1 through 90 and T1 through T8)PM2.5 — 3.59 tpy annual — — p. 11 ↗ Machine-extracted from an official permit limit table; header grouping requires second review.
DOCUMENT HISTORY
What this document says it changes amended or superseding permit document Explicitly supersedes the document dated 2022-11-21.
p. 1 ↗ , p. 3 ↗ QA NOTES
Ambiguity stays visible Machine-extracted candidate. Verify every reused value against the cited official PDF page. Verify table column grouping and any alternative models. Confirm multi-row and merged-column header association.