What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 74150-2, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

6 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
1, 2, 12, 17, 18, 19, and 36emergency engine generator setCaterpillar · 3516C-HD7 units2500 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
3 through 11 and 13 through 16emergency engine generator setCaterpillar · 3516C-HD13 units2500 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
20 through 35emergency engine generator setCaterpillar · 3516C-HD16 units2500 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
T1 through T4emergency engine generator setCaterpillar · 3516C4 units2000 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
Pollutantengine generator set1 unitsNo reliable per-unit rating transcribedSee operating-scope tablep. 10Machine-extracted from an official document equipment table; column grouping requires second review.
engine generator set unitsNo reliable per-unit rating transcribedSee operating-scope tablep. 10Machine-extracted from an official document equipment table; column grouping requires second review.

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
3 through 11, 13 through 16, 20 through 35,and T1 through T4100 hours/yearmbustion) shall be minimized to the maximum extent practical. (9VAC5-80-1180) [8/27/2024] 7. Operating Hours – Each individual emergency diesel engine gen-set (Ref. Nos. 3 through 11, 13 through 16, 20 through 35,and T1 through T4) shall not operate more than 100 hours per year for maintenance checks and readiness testing and no more than 500 hours per year for all purposes (as provided in Condition 3) combined. Each individual emergency diesel engine gen-set (Ref. Nos. 1, 2, 12, 17 through 19Machine-extracted normative operating-hours statement; second review pending.p. 8
3 through 11, 13 through 16, 20 through 35,and T1 through T4500 hours/year27/2024] 7. Operating Hours – Each individual emergency diesel engine gen-set (Ref. Nos. 3 through 11, 13 through 16, 20 through 35,and T1 through T4) shall not operate more than 100 hours per year for maintenance checks and readiness testing and no more than 500 hours per year for all purposes (as provided in Condition 3) combined. Each individual emergency diesel engine gen-set (Ref. Nos. 1, 2, 12, 17 through 19, and 36) shall not operate more than 35 hours per year for scheduled maintenanceMachine-extracted normative operating-hours statement; second review pending.p. 8
1, 2, 12, 17 through 19, and 3635 hours/yearar for maintenance checks and readiness testing and no more than 500 hours per year for all purposes (as provided in Condition 3) combined. Each individual emergency diesel engine gen-set (Ref. Nos. 1, 2, 12, 17 through 19, and 36) shall not operate more than 35 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT, as provided in Condition 3.c). Each individual emergency diesel engine gen-set (Ref. Nos. 1, 2, 12, 17 through 19, and 36) shall not operate more tMachine-extracted normative operating-hours statement; second review pending.p. 8
1, 2, 12, 17 through 19, and 36500 hours/yearoperate more than 35 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT, as provided in Condition 3.c). Each individual emergency diesel engine gen-set (Ref. Nos. 1, 2, 12, 17 through 19, and 36) shall not operate more than 500 hours per year for all purposes (as provided in Condition 3) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 8

Permitted emission limits

18 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 18 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
Ref. Nos. T1 through T4NOx as NO238.9 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 36NOx as NO248.06 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. T1 through T4NOx as NO24.1 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 36NOx as NO26.09 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. T1 through T4VOC1.1 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 36VOC1.21 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. T1 through T4PM100.6 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 36PM100.40 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. T1 through T4PM2.50.6 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 36PM2.50.40 lb/hrhourlyp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
All Engine Gen-Sets (Ref. Nos. 1 through 36 and T1 through T4)NOx as NO296.03 tpyannualcombinedp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
All Engine Gen-Sets (Ref. Nos. 1 through 36 and T1 through T4)NOx as NO251.66 tpyannualcombinedp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
All Engine Gen-Sets (Ref. Nos. 1 through 36 and T1 through T4)VOC10.81 tpyannualcombinedp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
All Engine Gen-Sets (Ref. Nos. 1 through 36 and T1 through T4)PM103.54 tpyannualcombinedp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
All Engine Gen-Sets (Ref. Nos. 1 through 36 and T1 through T4)PM2.53.54 tpyannualcombinedp. 10Machine-extracted from an official permit limit table; header grouping requires second review.
visible emissions5 percent opacityvisiblep. 11Machine-extracted from a page line in an older official PDF; literal context: Page 9 13. Visible Emission Limit – Visible emissions from each emergency diesel engine gen-set (Ref. Nos. 1 through 36 and T1 through T4) shall not exceed 5% opacity except during one six-minute period in any one hour in which visible emissions shall not exceed 10% opacity
visible emissions10 percent opacityvisiblep. 11Machine-extracted from a page line in an older official PDF; literal context: 13. Visible Emission Limit – Visible emissions from each emergency diesel engine gen-set (Ref. Nos. 1 through 36 and T1 through T4) shall not exceed 5% opacity except during one six-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by the EPA Method 9 (reference 40 CFR 60, Appendix A).
visible emissions20 percent opacityvisiblep. 11Machine-extracted from a page line in an older official PDF; literal context: During startup and shutdown, visible emissions from each engine gen-set (Ref. Nos. 1 through 36 and T1 through T4) shall not exceed 10% opacity except during one six-minute period in any one-hour in which visible emissions shall not exceed 20% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A).

DOCUMENT HISTORY

What this document says it changes

amended or superseding permit document

Explicitly supersedes the document dated 2018-04-24.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Verify table column grouping and any alternative models.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
  • Confirm multi-row and merged-column header association.
  • Older-PDF text fallback; verify row and unit alignment.
← Return to evidence index