Page-cited permit extraction

Digital Western Lands LLC

Loudoun Co., Virginia

QA status Machine-extractedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 74212-3, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

6 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
EG-121 through EG-260non-emergency engine generator setCaterpillar / Cummins140 units3000 kW eachdiesel fuel oilselective catalytic reduction (SCR); diesel oxidation catalyst; oxidation catalystSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
PBB1000-6 and PBB1000-7emergency engine generator setCaterpillar / Cummins2 units1000 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
EG-1 through EG-120non-emergency engine generator setCaterpillar / Cummins120 units3000 kW eachdiesel fuel oilselective catalytic reduction (SCR); diesel oxidation catalystSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
PBB1000-1 through PBB1000-5emergency engine generator setCaterpillar / Cummins5 units1000 kW eachdiesel fuel oilSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
PBB750-1 through PBB750-6emergency engine generator setCaterpillar / Cummins6 units750 kW eachdiesel fuel oilSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
engine generator set unitsNo reliable per-unit rating transcribedselective catalytic reduction (SCR); diesel oxidation catalystSee operating-scope tablep. 13Machine-extracted from an official document equipment table; column grouping requires second review.

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
PBB1000-1 through PBB1000-7 and PBB750-1 through PBB750-625 hours/yearlves fuel combustion) shall be minimized to the maximum extent practical. (9VAC5-80-1180) [10/10/2025] 10. Operating Hours – Each emergency diesel engine gen-set (Ref. Nos. PBB1000-1 through PBB1000-7 and PBB750-1 through PBB750-6) shall not operate more than 25 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT, as provided in Condition 6.c). Each emergency diesel engine gen-set (Ref. Nos. PBB1000-1 through PBB1000-7 and PBB750-1 through PBB750-6) shall notMachine-extracted normative operating-hours statement; second review pending.p. 11
PBB1000-1 through PBB1000-7 and PBB750-1 through PBB750-6500 hours/yearhan 25 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT, as provided in Condition 6.c). Each emergency diesel engine gen-set (Ref. Nos. PBB1000-1 through PBB1000-7 and PBB750-1 through PBB750-6) shall not operate more than 500 hours per year for all purposes (as provided in Condition 6) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 11

Permitted emission limits

54 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 54 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
Caterpillar (Controlled)*NOx as NO2controlled4.97 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)NOx as NO2uncontrolled49.68 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*NOx as NO2controlled5.01 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)NOx as NO2uncontrolled50.09 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*NOx as NO2controlled4.49 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)NOx as NO2uncontrolled53.41 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar (Controlled)*NOx as NO2controlled1.64 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)NOx as NO2uncontrolled5.46 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*NOx as NO2controlled0.62 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)NOx as NO2uncontrolled3.85 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*NOx as NO2controlled1.28 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)NOx as NO2uncontrolled3.21 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar (Controlled)*VOCcontrolled0.35 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)VOCuncontrolled0.58 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*VOCcontrolled0.42 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)VOCuncontrolled2.65 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*VOCcontrolled0.56 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
(Uncontrolled)VOCuncontrolled2.81 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar (Controlled)*SO2controlled0.05 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*SO2controlled0.05 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*SO2controlled0.05 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar (Controlled)*PMcontrolled0.74 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*PMcontrolled0.96 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*PMcontrolled1.07 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar (Controlled)*PM2.5controlled0.92 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*PM2.5controlled1.20 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*PM2.5controlled1.26 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar (Controlled)*PM10controlled0.92 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Cummins (Controlled)*PM10controlled1.20 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Rehlko (Controlled)*PM10controlled1.26 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW CaterpillarNOx as NO214.34 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW CumminsNOx as NO214.55 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
1,000 ekW CaterpillarNOx as NO219.52 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
1,000 ekW CumminsNOx as NO216.13 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW CaterpillarNOx as NO24.73 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW CumminsNOx as NO20.85 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
1,000 ekW CaterpillarNOx as NO22.78 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
1,000 ekW CumminsNOx as NO22.70 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW CaterpillarVOC1.91 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW CumminsVOC0.58 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedNOx as NO294.94 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
1,000 ekW Units CombinedNOx as NO20.94 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW Units CombinedNOx as NO20.60 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedNOx as NO267.68 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
1,000 ekW Units CombinedNOx as NO20.70 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
750 ekW Units CombinedNOx as NO21.01 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedVOC31.21 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedSO21.09 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedPM46.75 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedPM2.551.20 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
3,000 ekW Units CombinedPM1051.20 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
visible emissions5 percent opacityvisiblep. 16Machine-extracted from a page line in an older official PDF; literal context: 18. Visible Emission Limit – a. Visible emissions from each non-emergency engine gen-set (Ref. Nos. EG-1 through EG-260) shall not exceed 5% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A). This requirement applies at all times except during startup,
visible emissions10 percent opacityvisiblep. 16Machine-extracted from a page line in an older official PDF; literal context: PBB1000-7 and PBB750-1 through PBB750-6) shall not exceed 5% opacity except during one six-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by the EPA Method 9 (reference 40 CFR 60, Appendix A). This requirement applies at all times except during startup, shutdown,
visible emissions20 percent opacityvisiblep. 16Machine-extracted from a page line in an older official PDF; literal context: through EG-260, PBB1000-1 through PBB1000-7, and PBB750-1 through PBB750-6) shall not exceed 10% opacity except during one six-minute period in any one-hour in which visible emissions shall not exceed 20% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A).

DOCUMENT HISTORY

What this document says it changes

amended or superseding permit document

Explicitly supersedes the document dated 2024-10-31.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Verify table column grouping and any alternative models.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
  • Confirm multi-row and merged-column header association.
  • Older-PDF text fallback; verify row and unit alignment.
← Return to evidence index