Page-verified permit transcription

Iron Mountain Information Management LLC

Henrico County, Virginia

QA status VerifiedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A manually verified transcription of equipment groups and permit limits stated in Virginia DEQ permit 53266-1, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 3, p. 4.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

VERIFIED PERMIT TERMS

Equipment and limits,
kept separate from actual use.

This is a conservative transcription of reviewed permit sections, not an exhaustive legal digest. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

2 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
LS1-LS4emergency engine-generator setCaterpillar · 3512C4 units1500 kW eachdiesel36 hourshours/year; consecutive 12-month periodp. 4, p. 6
EG1-EG126engine-generator setCaterpillar or Cummins · C175-16 or C3000 D6e126 units3000 kW eachdieselSee operating-scope tablep. 4Permit allows manufacturer/model alternatives.

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
LS1-LS436 hours/yearhours/year; consecutive 12-month periodPermitted operating-hours field transcribed in the verified pilot equipment table.p. 4, p. 6

Permitted emission limits

12 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 12 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
EG1-EG126PM1.3 lb/hrhourlyper unitp. 8
EG1-EG126PM2.1 tpyannualcombinedp. 8
EG1-EG126PM101.5 lb/hrhourlyper unitp. 8
EG1-EG126PM102.4 tpyannualcombinedp. 8
EG1-EG126PM2.51.5 lb/hrhourlyper unitp. 8
EG1-EG126PM2.52.4 tpyannualcombinedp. 8
EG1-EG126NOx as NO258.4 lb/hrhourlyper unitp. 8
EG1-EG126NOx as NO295.7 tpyannualcombinedp. 8
EG1-EG126CO6.1 lb/hrhourlyper unitp. 8
EG1-EG126CO9.9 tpyannualcombinedp. 8
EG1-EG126VOC2.9 lb/hrhourlyper unitp. 8
EG1-EG126VOC4.7 tpyannualcombinedp. 8

DOCUMENT HISTORY

What this document says it changes

new minor NSR permit

No superseded-document date is asserted beyond the cited source wording.

p. 3, p. 4

QA NOTES

Ambiguity stays visible

  • Official PDF cover/permit heading checked in the manual second pass.
  • Value transcribed from official permit equipment/condition table; no totals calculated.
  • Permit allows manufacturer/model alternatives. — Value transcribed from official permit equipment/condition table; no totals calculated.
  • Directly stated permitted limit; not an actual emissions value.
← Return to evidence index