Page-cited permit extraction

Iskander (LC-1A) Jamshid (LC-1B) Kaveh (LC2) Lohrasp Ventures (LC3)

Loudoun Co., Virginia

QA status Machine-extractedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 74155-4, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

5 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348emergency engine generator setCaterpillar · C175-16 non-75 units3000 kW eachdiesel fuel oilselective catalytic reduction (SCR)See operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
FP-3fire-pump engine1 units48 kW eachdiesel fuel oilSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
1 through 88emergency engine generator setCaterpillar · C175-1688 units3000 kW eachdiesel fuel oilSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
89 through 92, 98 through 107, 121, 123 through 128, and 137 through 142emergency engine generator setCaterpillar · C175-1627 units3000 kW eachdiesel fuel oilSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.
FP-1Afire-pump engineJohn Deere · 4045TF290 stationary1 units64 bhp eachdiesel fuel oilSee operating-scope tablep. 6Machine-extracted from an official document equipment table; column grouping requires second review.

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
1 through 92, 98 through 107, 121, 123 through 128, and 137 through 1429 hours/yearioning during the integration operational period. (9VAC5-80-1180) [9/15/2023] 10. Operating Hours – Each individual emergency diesel engine gen-set (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142) shall not operate more than 9 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT) (as provided in Condition 8c.). Each individual emergency diesel engine gen-set (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, andMachine-extracted normative operating-hours statement; second review pending.p. 11
1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142500 hours/yearscheduled maintenance checks and readiness testing (Scheduled MCRT) (as provided in Condition 8c.). Each individual emergency diesel engine gen-set (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142) shall not operate more than 500 hours per year for all purposes (as provided in Condition 8) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 11
FP-1A and FP-340 hours/yearr the most recently completed calendar month to the individual monthly totals for the preceding 11 months. (9VAC5-80-1180) [9/15/2023] 11. Operating Hours (Fire Pump Engines) – Each fire pump diesel engine (Ref. No. FP-1A and FP-3) shall not operate more than 40 hours per year for all purposes (as provided in Condition 9) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 11

Permitted emission limits

42 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 42 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
Caterpillar C175-16 (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142)NOx as NO258.51 lb/hrhourlyper unitp. 13Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142)NOx as NO214.31 lb/hrhourlyper unitp. 13Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142)VOC2.31 lb/hrhourlyper unitp. 13Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142)PM100.78 lb/hrhourlyper unitp. 13Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 (Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142)PM2.50.78 lb/hrhourlyper unitp. 13Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 Ref. Nos. 93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348) UncontrolledNOx as NO2uncontrolled58.02 lb/hrhourlyper unitp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Controlled with SCRNOx as NO2controlled3.77 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 Ref. Nos. 93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348) UncontrolledNOx as NO2uncontrolled6.05 lb/hrhourlyper unitp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 Ref. Nos. 93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348) UncontrolledVOCuncontrolled2.31 lb/hrhourlyper unitp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 Ref. Nos. 93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348) UncontrolledPM10uncontrolled1.50 lb/hrhourlyper unitp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Caterpillar C175-16 Ref. Nos. 93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348) UncontrolledPM2.5uncontrolled1.50 lb/hrhourlyper unitp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
John Deere 4045TF290 (Ref. No. FP-1A)NOx as NO20.62 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
John Deere 4045TF290 (Ref. No. FP-1A)PM100.05 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
John Deere 4045TF290 (Ref. No. FP-1A)PM2.50.05 lb/hrhourlyp. 14Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. No. FP-3NOx as NO20.39 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. No. FP-3NOx as NO20.08 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. No. FP-3VOC0.03 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. No. FP-3PM100.03 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. No. FP-3PM2.50.03 lb/hrhourlyp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)NOx as NO280.97 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)NOx as NO210.68 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
With SCRNOx as NO2controlled2.71 tpyannualp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 142 and 301 through 348 All Operations (All Units Combined)NOx as NO294.36 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)NOx as NO244.19 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)NOx as NO22.44 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
With SCRNOx as NO2controlled9.55 tpyannualp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 142 and 301 through 348 All Operations (All Units Combined)NOx as NO256.18 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)VOC8.36 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)VOC1.15 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
With SCRVOCcontrolled4.48 tpyannualp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 142 and 301 through 348 All Operations (All Units Combined)VOC13.99 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)PM102.87 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)PM100.34 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
With SCRPM10controlled1.34 tpyannualp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 142 and 301 through 348 All Operations (All Units Combined)PM104.55 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)PM2.52.87 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 92, 98 through 107, 121, 123 through 128, and 137 through 142 (All Units Combined)PM2.50.34 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
With SCRPM2.5controlled1.34 tpyannualp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
Ref. Nos. 1 through 142 and 301 through 348 All Operations (All Units Combined)PM2.54.55 tpyannualcombinedp. 15Machine-extracted from an official permit limit table; header grouping requires second review.
visible emissions5 percent opacityvisiblep. 16Machine-extracted from a page line in an older official PDF; literal context: emergency diesel engine gen-set (Ref. Nos. 93 through 97, 108 through 120, 122, 129 through 136, and 301 through 348), and fire pump diesel engine (Ref. Nos. FP-1A and FP-3) exhausts shall not exceed 5% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by EPA Method 9
visible emissions10 percent opacityvisiblep. 16Machine-extracted from a page line in an older official PDF; literal context: through 136, and 301 through 348), and fire pump diesel engine (Ref. Nos. FP-1A and FP-3) exhausts shall not exceed 5% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A). This condition applies at all times except during
visible emissions20 percent opacityvisiblep. 16Machine-extracted from a page line in an older official PDF; literal context: During startup and shutdown, visible emissions from each emergency diesel engine gen-set shall not exceed 10% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 20% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A).

DOCUMENT HISTORY

What this document says it changes

amended or superseding permit document

Explicitly supersedes the document dated 2023-09-15.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Verify table column grouping and any alternative models.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
  • Confirm multi-row and merged-column header association.
  • Older-PDF text fallback; verify row and unit alignment.
← Return to evidence index