QA status Machine-extractedRelease dated July 29, 2026
EVIDENCE NOTE
What the public record says
A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 71804-4, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.
The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.
How to read the status
Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.
MACHINE-EXTRACTED CANDIDATE
Equipment and limits, kept separate from actual use.
These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.
Permitted equipment
1 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.
Reference
Equipment / model
Count / rating
Fuel / controls
Stated operating field
Source
engine generator set—
1 unitsNo reliable per-unit rating transcribed
——
See operating-scope table—
p. 1 ↗Machine-extracted from explicit permit prose: 1-5) and the Waukesha VHP670DS existing engine generators (Ref
Operating scope
Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.
Reference
Limit
Basis
Source
1-8
100 hours/year
e hours of 6:00 p. m. and 6:00 a.m. Eastern Daylight Time, unless requested by the permittee and prior approval is provided by DEQ- NRO. (9 VAC 5-80-1180) Operating Hours - Each emergency diesel engine-generator set (Ref. Nos. 1-8) shall not operate more than 100 hours per year, calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12 month period shall be demonstrated monthly by adding the total operating hours for the most recently completed calendMachine-extracted normative operating-hours statement; second review pending.
2 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.
Inspect 2 transcribed limit rows
Reference
Pollutant
Limit
Basis / scope
Source
visible emissions—
5 percent opacityvisible
——
p. 8 ↗Machine-extracted from a page line in an older official PDF; literal context: (9 VAC 5-80-1180a nd 9 VAC 5-50-260) 11 Visible Emission Limit - Visible emissions from each emergency diesel engine-generator exhaust (Ref. Nos. 1-8) shall not exceed 5% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by
visible emissions—
10 percent opacityvisible
——
p. 8 ↗Machine-extracted from a page line in an older official PDF; literal context: 11 Visible Emission Limit - Visible emissions from each emergency diesel engine-generator exhaust (Ref. Nos. 1-8) shall not exceed 5% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A). This condition applies at all times
DOCUMENT HISTORY
What this document says it changes
permit to construct and operate
No superseded-document date is asserted beyond the cited source wording.