Comcast Cablevision of Virginia Incorporated

Prince William Co., Virginia

QA status Machine-extractedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 72374-4, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

1 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
engine generator setCaterpillar · 3512C 2206 bhp and 39 units1500 kW eachdiesel fuel oilSee operating-scope tablep. 4Machine-extracted from explicit permit prose: Capacity Requirements 9 VAC 5-50-410 Caterpillar Model 3512C 2206 bhp and 3 Diesel Engine Generator Set 1500 ekW 9 VAC 5-60-100 9 VAC 5-50-410 Caterpillar Model 3512C 2206 bhp 4 Diesel Engine Generator Set 1500 ekW and 9 VAC 5-60-100 Eaumment Dermitted prior to the date of this permit: Reference No

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
500 hours/yearabnormal event external to the ISO service territory that may require ISO action. c For periodic maintenance, testing, and operational training (9VAC 5-30-1130) 6. Operating ^iours-Each diesel engine generator set (Pef.Nos.3and 4) shall not operate more than 500 hours per year,calculated monthly as the sum of each consecutive 12 month period Compliance forthe consecutive 12month period shall be demonstrated monthly by adding the total forthe most recently completed calendar month to the indivMachine-extracted normative operating-hours statement; second review pending.p. 6

Permitted emission limits

1 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 1 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
each engine-generator set (Ref.Nos.3 and 4)NOx as NO27.3 tpyannualp. 7Machine-extracted from a page line in an older official PDF; literal context: 10. Emission Limits-Emissions from the operation of each engine-generator set (Ref.Nos.3 and 4) shall not exceed the limits specified below; Nitrogen Oxides (as NO^) 29.13lbs^hr 7.3tons/yr These emissions are derived from the estimated overall emission contribution from

DOCUMENT HISTORY

What this document says it changes

amended or superseding permit document

Explicitly supersedes the document dated 2012-10-18.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Prose fallback; verify equipment grouping.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
  • Older-PDF text fallback; verify row and unit alignment.