Page-cited permit extraction

Equinix, LLC - DC 14

Prince William Co., Virginia

QA status Machine-extractedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 73200-2, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

1 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
emergency engine generator set7 unitsNo reliable per-unit rating transcribeddiesel fuel oilSee operating-scope tablep. 1Machine-extracted from explicit permit prose: Leland: Attached is a minor amendment to your permit to construct and operate seven diesel engine-driven emergency generators at your computer data center located in Manassas, Virginia, in accordance with the provisions of th

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
2279 hours/year: a. If compliance with the facility-wide NOx emission limit, Condition 10, is determined using the calculation method specified in Condition 11 a, the cumulative hours of operation for all emergency generators (Ref. # EGU 1 through EGU 7) shall be limited to 2279 hours per year, calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month period shall be demonstrated monthly by adding the total for the most recently completed calendar month to theMachine-extracted normative operating-hours statement; second review pending.p. 5

Permitted emission limits

5 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 5 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
NOx as NO246.9 tpyannualp. 5Machine-extracted from a page line in an older official PDF; literal context: totals for the preceding 11 months b. If compliance with the facility-wide NOx emission limit, Condition 10, is determined using the method specified in Condition 11b, the annual NOx emission limit of 46.9 TPY shall be the limiting factor. Annual NOx emissions shall be calculated on a monthly basis as
NOx as NO246.9 tpyannualp. 7Machine-extracted from a page line in an older official PDF; literal context: 2 exceed: NOx = 46.9 tons/year. Compliance shall be demonstrated in accordance with Conditions 4 and 11.
visible emissions5 percent opacityvisiblep. 8Machine-extracted from a page line in an older official PDF; literal context: (9 VAC 5-80-1180 and 9 VAC 5-50-260) 12. Visible Emission Limit - Visible emissions from each emergency generator (Ref. # EGU1 thru EGU7) shall not exceed 5% opacity except during one six-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by the EPA
visible emissions10 percent opacityvisiblep. 8Machine-extracted from a page line in an older official PDF; literal context: 12. Visible Emission Limit - Visible emissions from each emergency generator (Ref. # EGU1 thru EGU7) shall not exceed 5% opacity except during one six-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by the EPA Method 9 (reference 40 CFR 60, Appendix A). During startup and shutdown, visible .
visible emissions20 percent opacityvisiblep. 8Machine-extracted from a page line in an older official PDF; literal context: Method 9 (reference 40 CFR 60, Appendix A). During startup and shutdown, visible . emissions shall not exceed 10% opacity, except for one six-minute interval not to exceed 20% opacity. (9 VAC 5-80-1180, 9 VAC 5-50-260 and 9 VAC 5-170-160)

DOCUMENT HISTORY

What this document says it changes

permit to construct and operate

No superseded-document date is asserted beyond the cited source wording.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Prose fallback; verify equipment grouping.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
  • Older-PDF text fallback; verify row and unit alignment.
← Return to evidence index