Page-cited permit extraction

Nova Mango Farms LLC

Prince William Co., Virginia

QA status Machine-extractedRelease dated July 29, 2026

EVIDENCE NOTE

What the public record says

A machine-extracted candidate of equipment groups and permit limits stated in Virginia DEQ permit 74216-4, with one-based PDF page citations. Permitted terms do not establish actual operation or emissions.

Primary sourceVirginia DEQ permit document

Virginia Department of Environmental Quality

Open original source ↗

Summary fields cite p. 1, p. 3.

What this record does not establish

The source confirms the document and its stated fields. This profile does not infer actual emissions, compliance history, operating status, facility capacity or environmental impact where those facts are not established by the cited document.

How to read the status

Issued means the agency granted the permit subject to its conditions. It does not mean every permitted unit is operating, that maximum permitted emissions occur, or that later amendments do not exist.

MACHINE-EXTRACTED CANDIDATE

Equipment and limits,
kept separate from actual use.

These page-cited rows are machine-extracted and still require a second manual review. Verify every reused value against the linked official PDF. Page numbers refer to the one-based position in the linked PDF. Blank values are not zero.

Permitted equipment

9 document-defined equipment groups. Counts and per-unit ratings are transcribed; combined capacity is not calculated.

ReferenceEquipment / modelCount / ratingFuel / controlsStated operating fieldSource
69 through 102 (Group 5)emergency engine generator setMTU · 20V4000G74S34 units2800 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
117 through 123 and 130 through 132 (Group 6)emergency engine generator setMTU · 12V4000G84S7 units1750 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
CT22 through CT31cooling tower unitsNo reliable per-unit rating transcribedSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
1 through 68 (Group 1)emergency engine generator setCaterpillar · 3516E68 units2750 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
103 through 116 and 124 through 129 (Group 2)emergency engine generator setCaterpillar · 3512C14 units1750 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
133 (Group 3)emergency engine generator set units560 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
134 and 135 (Group 4)fire-pump engine units274 kW eachdiesel fuel oilSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
CT1 through CT21cooling tower unitsNo reliable per-unit rating transcribedSee operating-scope tablep. 5Machine-extracted from an official document equipment table; column grouping requires second review.
Pollutantcooling tower1 unitsNo reliable per-unit rating transcribedSee operating-scope tablep. 12Machine-extracted from an official document equipment table; column grouping requires second review.

Operating scope

Authorized hours, time windows or an explicit finding that no numeric annual-hour cap was located in the reviewed sections.

ReferenceLimitBasisSource
1 through 13228 hours/yearnd for commissioning during the integration operational period. (9 VAC 5-80-1180) [2/27/2024] 8. Operating Hours – (Group 1, Group 2, Group 5, and Group 6) – Each individual emergency diesel engine gen-set (Ref. Nos. 1 through 132) shall not operate more than 28 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT). Each individual emergency diesel engine gen-set (Ref. Nos. 1 through 132) shall not operate more than 500 hours per year for all purposes (as provMachine-extracted normative operating-hours statement; second review pending.p. 8
1 through 132500 hours/yeargine gen-set (Ref. Nos. 1 through 132) shall not operate more than 28 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT). Each individual emergency diesel engine gen-set (Ref. Nos. 1 through 132) shall not operate more than 500 hours per year for all purposes (as provided in Condition 6) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 8
13328 hours/yearNova Mango Farms LLC Registration Number: 74216 February 27, 2024 Page 7 9. Operating Hours – (Group 3) – The emergency diesel engine gen-set (Ref. No. 133) shall not operate more than 28 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT). The emergency diesel engine gen-set (Ref. No. 133) shall not operate more than 100 hours per year for all purposes (as provided in Condition 6) coMachine-extracted normative operating-hours statement; second review pending.p. 9
133100 hours/yearGroup 3) – The emergency diesel engine gen-set (Ref. No. 133) shall not operate more than 28 hours per year for scheduled maintenance checks and readiness testing (Scheduled MCRT). The emergency diesel engine gen-set (Ref. No. 133) shall not operate more than 100 hours per year for all purposes (as provided in Condition 6) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 9
134 and 135100 hours/yeartotal for the most recently completed calendar month to the individual monthly totals for the preceding 11 months. (9 VAC 5-80-1180) [2/27/2024] 10. Operating Hours – (Group 4) – Each fire pump diesel engine (Ref. Nos. 134 and 135) shall not operate more than 100 hours per year for all purposes (as provided in Condition 7) combined. The annual limits for hours of operation shall be calculated monthly as the sum of each consecutive 12-month period. Compliance for the consecutive 12-month periodMachine-extracted normative operating-hours statement; second review pending.p. 9

Permitted emission limits

44 pollutant, unit-group and limit rows. These are permit terms, not measured or actual emissions.

Inspect 44 transcribed limit rows
ReferencePollutantLimitBasis / scopeSource
Group 1 (Ref. Nos. 1 through 68)NOx as NO252.91 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)NOx as NO234.19 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 3 (Ref. No. 133)NOx as NO25.92 lb/hrhourlyp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 4 (Ref. Nos. 134 and 135)NOx as NO22.89 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)NOx as NO253.36 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)NOx as NO233.81 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)NOx as NO210.22 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)NOx as NO25.88 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 3 (Ref. No. 133)NOx as NO25.18 lb/hrhourlyp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 4 (Ref. Nos. 134 and 135)NOx as NO22.53 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)NOx as NO212.09 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)NOx as NO25.52 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)VOC0.89 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 3 (Ref. No. 133)VOC1.92 lb/hrhourlyp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 4 (Ref. Nos. 134 and 135)VOC0.94 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)VOC2.35 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)VOC1.39 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)PM100.85 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)PM100.54 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 3 (Ref. No. 133)PM101.30 lb/hrhourlyp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 4 (Ref. Nos. 134 and 135)PM100.42 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)PM101.28 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)PM100.46 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)PM2.50.85 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1 (Ref. Nos. 1 through 68)PM2.50.54 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 3 (Ref. No. 133)PM2.51.30 lb/hrhourlyp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 4 (Ref. Nos. 134 and 135)PM2.50.42 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)PM2.51.28 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 5 (Ref. Nos. 69 through 102)PM2.50.46 lb/hrhourlyper unitp. 11Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1, Group 2, Group 5, and Group 6 (Ref. Nos. 1 through 132)NOx as NO294.01 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1, Group 2, Group 5, and Group 6 (Ref. Nos. 1 through 132)NOx as NO226.13 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1, Group 2, Group 5, and Group 6 (Ref. Nos. 1 through 132)VOC12.97 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1, Group 2, Group 5, and Group 6 (Ref. Nos. 1 through 132)PM103.48 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Group 1, Group 2, Group 5, and Group 6 (Ref. Nos. 1 through 132)PM2.53.48 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Cooling Towers (CT1 through CT31)PM107.60 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Cooling Towers (CT1 through CT31)PM2.57.60 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Total EmissionsNOx as NO294.59 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Total EmissionsNOx as NO226.64 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Total EmissionsVOC13.16 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Total EmissionsPM1011.19 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
Total EmissionsPM2.511.19 tpyannualp. 12Machine-extracted from an official permit limit table; header grouping requires second review.
visible emissions5 percent opacityvisiblep. 13Machine-extracted from a page line in an older official PDF; literal context: 19. Visible Emission Limit – Visible emissions from each emergency diesel engine gen-set (Ref. Nos. 1 through 133) and each fire pump diesel engine (Ref. Nos. 134 and 135) exhausts shall not exceed 5% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by EPA Method 9 (reference
visible emissions10 percent opacityvisiblep. 13Machine-extracted from a page line in an older official PDF; literal context: (Ref. Nos. 1 through 133) and each fire pump diesel engine (Ref. Nos. 134 and 135) exhausts shall not exceed 5% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 10% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A). This condition applies at all times except during startup, shutdown
visible emissions20 percent opacityvisiblep. 13Machine-extracted from a page line in an older official PDF; literal context: During startup and shutdown, visible emissions from each emergency diesel engine gen-set shall not exceed 10% opacity except during one 6-minute period in any one hour in which visible emissions shall not exceed 20% opacity as determined by EPA Method 9 (reference 40 CFR 60, Appendix A).

DOCUMENT HISTORY

What this document says it changes

amended or superseding permit document

Explicitly supersedes the document dated 2023-04-11.

p. 1, p. 3

QA NOTES

Ambiguity stays visible

  • Machine-extracted candidate. Verify every reused value against the cited official PDF page.
  • Verify table column grouping and any alternative models.
  • Confirm whether the limit is per unit, combined, or limited to testing/maintenance.
  • Confirm multi-row and merged-column header association.
  • Older-PDF text fallback; verify row and unit alignment.